CHARACTERISTICS
Technology: Turbine.
Fluid: For nitrogen.
Installation: Flange.

Process pressure:
• Min.: 0 Pa (0 psi).
• Max.: 10,000,000 Pa (1,450.38 psi).

Volumetric flow rate:
• Min.: 25 m³/h (882.9 ft³/h).
• Max.: 25,000 m³/h (882,866.7 ft³/h).

DESCRIPTION
Application Suitable for natural, non-aggressive and manufactured gases; nitrogen, carbon dioxide and propane; and other gases. With electronic counter (powered by batteries lasting at least 6 years) High measuring accuracy Flow indicator Low-torque measuring system Special design for aggressive gases is available LF and HF impulse generator in counter head Resettable totalizer Electronic suppression of over-travel is possible Power output (external power unit required) Explosion protection: II 2 G EEx ib [ia] II C T4/T3 Gas may flow horizontally or vertically 2-channel-measurements with pulse comparison (optional) Tested according to DIN-DVGW Max. admissible pressure PS = 100 bar Max. admissible pressure pmax up to 100 bar Meter sizes from Qmax 25 m³/h to Qmax 25,000 m³/h Connection -Standard: Flange bore up to PN 100 and ANSI 600 in DN 50 to DN 600 -Optional: Sandwich design DN 50 to DN 250 Sandwich design with threaded connection DN 25 and DN 40.

Device for Secondary Metering. Suitable for natural, non-aggressive and manufactured gases; nitrogen, carbon dioxide and propane; and other gases upon enquiry. Mechanical counter head for continuous registration and display of total volume without electrical power supply. High measuring accuracy. Gas may flow horizontally or vertically. Optionally with mechanical drive shaft. Special design for aggressive gases is available.

PRODUCTS DETAILS: 
• Max. admissible pressure PS = 100 bar.
• Max. admissible pressure pmax up to 100 bar.
• Meter sizes from Qmax 100 m³/h to Qmax 25000 m³/h.
• Measuring range max. 1 : 16.
• Connection DIN flange PN 10, PN 16, PN 25, PN 40, PN 100 and Flanges according to ANSI 150, ANSI 300, ANSI 600 in DN 50, DN 80, DN 100, DN 150, DN 200, DN 250, DN 300, DN 400, DN 500, DN 600 or
• Single-flange design for DN 50 to DN 250.